Diamond Burs Presented at the American Dental Association Annual Scientific Session at
By Prof. Gary R. Johnson, DDS,
|
|||
Suggested Cleaning/Sterilization Protocol For Diamond Rotary Instruments |
|||
| 1. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 20 minutes with Pro Portion® (Sultan)
2. 3 rinses in distilled water 3. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 20 minutes with distilled water 4. Sterilize in autoclave or dry heat oven |
|||
|
Do You Want to Re-use Diamond Rotary Instruments? |
|||
|
- All surgical instruments that are disposable are single use only! - Cross contamination risk - Liability - Decreased cutting efficiency - Increased operator fatigue - Increased heat build-up - Increased risk of pulp damage - Increased chair time - Increased staff injury risk - Increased staff time for cleaning/sterilize |
|||
|
|
|||
|
![]() |
![]() |
|
|
Contaminated Diamond Bur Used to prepare one molar for crown SS White 856-016C Piranha Diamond SEM 40X WD25.6mm 10.0kV x40 |
Contaminated Diamond Bur Used to prepare one molar for crown SS White 856-016C Piranha Diamond SEM 100X WD16.0mm 10.0kV x100 |
Contaminated Diamond Bur Used to prepare one molar for crown SS White 856-016C Piranha Diamond SEM 600X WD15.7mm 10.0kV x600 |
|
Ultrasonic Cleaning Used to prepare one molar for crown SS White 856-016C Piranha Diamond SEM 40X WD26.7mm 10.0kV x40 |
Ultrasonic Cleaning Used to prepare one molar for crownSS White 856-016C Piranha Diamond SEM 100X WD15.7mm 10.0kV x100 |
Ultrasonic Cleaning Used to prepare one molar for crown SS White 856-016C Piranha Diamond SEM 600X WD15.7mm 10.0kV x600 |
|
| 1. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 20 minutes with Pro Portion® (Sultan)
2. 3 rinses in distilled water 3. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 20 minutes with distilled water |
|||
Debris Remaining after Ultrasonic Cleaning Used to prepare one molar for crown SS White 856-016C Piranha Diamond SEM 600X WD15.7mm 10.0kV x600 |
|||
| 1. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 10 minutes with Pro Portion® (Sultan)
2. 3 rinses in distilled water 3. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 5 minutes with distilled water |
|||
| All images on this page copyright of Dr. Gary R. Johnson 2006 | |||