Banner

Research

Diamond Burs

Presented at the American Dental Association Annual Scientific Session at Las Vegas Nevada on October 17, 2006

By

Prof. Gary R. Johnson, DDS, MAGD
University
of Illinois-Chicago Medical Center College of Medicine Craniofacial Center: Chicago Illinois
Michelle Johnson (Research Assistant) - University of Illinois-Chicago:
Chicago Illinois
Brendan Durkin (Research Assistant) –
Benedictine University: Lisle Illinois

  • Suggested Cleaning/Sterilization Protocol For Diamond Rotary Instruments

1. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 20 minutes with Pro Portion® (Sultan)

2. 3 rinses in distilled water

3. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 20 minutes with distilled water

4. Sterilize in autoclave or dry heat oven

  • Do You Want to Re-use Diamond Rotary Instruments?

- All surgical instruments that are disposable are single use only!

- Cross contamination risk

- Liability

- Decreased cutting efficiency

- Increased operator fatigue

- Increased heat build-up

- Increased risk of pulp damage

- Increased chair time

- Increased staff injury risk

- Increased staff time for cleaning/sterilize

New Unused Diamond Bur

SS White New Piranha 856-016C Diamond

SEM 40X

WD26.1mm  10.0kV  x40

Contaminated Diamond Bur

Used to prepare one molar for crown

SS White 856-016C Piranha Diamond

SEM 40X

WD25.6mm  10.0kV  x40

Contaminated Diamond Bur

Used to prepare one molar for crown

SS White 856-016C Piranha Diamond

SEM 100X

WD16.0mm  10.0kV  x100

Contaminated Diamond Bur

Used to prepare one molar for crown

SS White 856-016C Piranha Diamond

SEM 600X

WD15.7mm  10.0kV  x600

Ultrasonic Cleaning

Used to prepare one molar for crown

SS White 856-016C Piranha Diamond

SEM 40X

WD26.7mm  10.0kV  x40

Ultrasonic Cleaning

Used to prepare one molar for crown

SS White 856-016C Piranha Diamond

SEM 100X

WD15.7mm  10.0kV  x100

Ultrasonic Cleaning

Used to prepare one molar for crown

SS White 856-016C Piranha Diamond

SEM 600X

WD15.7mm  10.0kV  x600

1. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 20 minutes with Pro Portion® (Sultan)

2. 3 rinses in distilled water

3. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 20 minutes with distilled water

Debris Remaining after Ultrasonic Cleaning

Used to prepare one molar for crown

SS White 856-016C Piranha Diamond

SEM 600X

WD15.7mm  10.0kV  x600

1. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 10 minutes with Pro Portion® (Sultan)

2. 3 rinses in distilled water

3. Coltčne Whaledent UC300 Biosonic® ultrasonic cleaning in separate glass beaker for 5 minutes with distilled water

All images on this page copyright of Dr. Gary R. Johnson 2006